GAS CYLINDERS ( TS 11169 )

Material: Steel, Seamless Cash

Color: Grey (RAL 7000)

50 l Water Volume: 250 Bar Test Pressure

Filling Factor: 0.75 kg/L



VALVES ( TS 1520 )

Material: Brass

Output Size: W 21.8 x 25.4 mm in the 14 teeth (external)



APPEARANCE AND ODOR

Colorless and odorless gas.

STORAGE

It’s stored in tubes which are appropriate to TS 11169 Standard/Sheet 5-6 or in special polyurethane-insulated tanks or containers of liquid.



FIRE AND EXPLOSION HAZARD DATA

It is not flammable or caustic. It is a fire-fighting agent.Overheated full filled tubes can cause an explosion. The tubes should be cooled by spraying water and safely relocated if they are exposed to fire.



HEALTH HAZARD INFORMATION

Normal level of inhalation may cause simple symptoms of drowning. Medium level of inhalation may cause headache, nausea, vomiting and fainting. High level of inhalation may cause coma through lack of blood circulation and even death. CO2 is known as the most powerful cerebral vasodilator.



METHODS OF EMERGENCY AND FIRST AID

Middle and high level aspiration urgently taken to the nearest health facility.

Chemical Symbol Sublimation Point Gas Density Liquid Density Specific Gravity Liquid-Gas Expansion Ratio Ratio in Air
CO2 - 78,44 ° C 1,97 g/l 0,762 g/ml 1,528 1:556 % 0,0335



pdf  Carbon Dioxide Gas MSDS.pdf 



 © 2008 ÇUKUROVA INDUSTRIAL AND MEDICAL GASES INC. Designed by : Interkey 

About Us | Out Affiliates | Human Resources | Fire Extinguishers With Powder | Fire Extinguishers With CO2 | Fire Extinguishers With Halocarbon | Fire Extinguishers With Foam | Dry Ice | Argon |
Carbon Dioxide | Oxygen | Acetylene | Nitrogen | Filling Services| | Testing and Paint-Maintenance Unit | Education - Practice Services About Fire | Ammonia |